Neural Network Effect of Composition and Cooling Rate on
Stainless
Steel Weld Ferrite Number
Instructions: Type in the Stainless Steel Composition press 'Calculate'.
Composition of the steel
Thickness of steel (in.):
Welding Process:
Arc Welding Process Parameters
Voltage (V):
Current (Amps):
Speed (in/min):
This takes about 45 seconds when the server is not busy, longer if it
is.
If you get a "no data" result, please try again. If you continue to experience problems, contact skhurana@ewi.org
Limitations
| Fe |
Cr |
Ni |
C |
N |
Mo |
Mn |
Si |
Cu |
Ti |
Nb |
V |
Co |
Log Cooling Rate |
| 45.60 |
14.74 |
4.61 |
0.008 |
0.01 |
0.01 |
0.35 |
0.03 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
1 |
| 72.52 |
32 |
33.5 |
0.2 |
0.33 |
6.85 |
12.67 |
1.3 |
3.04 |
0.54 |
0.88 |
0.23 |
0.45 |
6.54 |
Predictions as a function of cooling rate should be considered to be
qualitative and probably are more appropriate
at high cooling rates (>
10,000 K/s). If you have any questions or need an excel spreadsheet
form of this calcualtion,
please contact Dr.
J. M. Vitek.
References
- J. M. Vitek, S. A. David, C. R. Hinman, Welding
Journal, 2003, Vol. 82, No 1, 10s-17s
- J. M. Vitek, S. A. David, C. R. Hinman, Welding Journal, 2003, Vol.82, No 2, 43s-50s
Disclaimer
The programs and procedures on this website are provided
"AS IS" without warranty of any kind. EWI makes no warranties,
express or implied, that the programs and procedures
are free of error, or are consistent with any particular
standard of merchantability, or that they will meet the
requirements for any particular application.
THE PROGRAMS AND PROCEDURES SHOULD NOT BE RELIED
ON FOR SOLVING A PROBLEM WHOSE INCORRECT SOLUTION
COULD RESULT IN INJURY TO A PERSON OR LOSS OF PROPERTY.
Use of the programs or procedures in such a manner,
it is at your own risk. Edison Welding Institute disclaims all
liability for direct, incidental or consequential damages
resulting from the use of programs or procedures on this website.
The information herein was prepared as an account of work sponsored
by an agency of the United States Government at the Oak Ridge National Laboratory.
Neither the United States Government nor any agency thereof, nor any of its employees,
nor UT-Battelle or any other United States Government contractors,
subcontractors or their employees, makes any warranty, express or implied,
or assumes any legal liability or responsibility for the accuracy, completeness,
or any third party’s use or the results of such use of any information or process
disclosed, ore represents that its use would not infringe privately owned rights |
The on-line calculations are for educational purposes only and are based on published work in the literature. Some of the modules were developed at Oak Ridge National Laboratory (ORNL) and have been made available to EWI members as a part of the memorandum of understanding between ORNL and EWI. For additional information, please contact Edison Welding Institute
|